IEC 60335-2-108:2024

Title
Abstract

IEC 60335-2-108:2024 is available as IEC 60335-2-108:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60335-2-108:2024 deals with the safety of electrolysers that produce low viscosity, ionized liquids intended for use as detergent free wash water in appliances for household and similar purposes and which conform with the standards applicable to such appliances. It applies to electrolysers tested separately, under the most severe conditions that can be expected to occur in normal use, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances.
Examples of appliances that can contain electrolysers are:
- dishwashers (IEC 60335-2-5);
- washing machines (IEC 60335-2-7);
- appliances producing wash water for hygiene purposes.
This standard does not supersede the requirements of standards relevant to the particular appliance in which the electrolyser is used. However, if the electrolyser used complies with this standard, the tests for the electrolyser specified in the particular appliance standard can be unnecessary in the particular appliance or assembly. If the electrolyser control system is associated with the particular appliance control system, additional tests can be necessary on the final appliance. Guidance for additional requirements to be considered for inclusion in the end product standards for appliances that use electrolysers is given in informative Annex BB.
Attention is drawn to the fact that:
- for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
- in many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
This standard does not apply to
- appliances intended exclusively for industrial purposes;
- appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the text has been aligned with IEC 60335-1:2020;
b) some notes have been converted to normative text (Clause 1, 22.012);
c) application of test probe 19 has been introduced (8.1.1, 20.2, B22.3, B22.4);
d) addition of external accessible surface temperatures (Clause 11).
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1:2020 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

Issue Date

2024-03-22

Category

HOUS

Included in IECEE System

2024-04-09

Purchase webstore
Test Report Form

No information declared

Testing Equipment List

No information declared

DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

No information declared

Laboratory Name

City

Country

Responsible National Certification Body

Arnhem

Netherlands

Shanghai 200436

China

Id

Name

City

Country

13360

Arnhem

Netherlands

No information declared