IEC 60825-2:2021

Title
Abstract

IEC 60825-2:2021 provides requirements and specific guidance for the safe operation and maintenance of optical fibre communication systems (OFCSs). In these systems, optical power is possibly accessible outside the confines of the transmitting equipment and/or at great distance from the optical source.
This document requires the assessment of hazard level at each accessible location of the OFCS as a replacement for product classification according to IEC 60825-1. It applies to the installed OFCS as an engineered, end-to-end assembly for the generation, transfer and receipt of optical radiation arising from lasers, light-emitting diodes (LEDs) or optical amplifiers, in which the transference is by means of optical fibre for communication and/or control purposes.
Individual components and subassemblies that fall under the definition of a laser product are subject to the applicable subclause(s) of IEC 60825-1. This document is applicable to individual components and subassemblies intended to be installed within OFCSs.
This document does not apply to optical fibre systems primarily designed to transmit optical power for applications such as material processing or medical treatment.
In addition to the hazards resulting from laser radiation, OFCSs possibly give rise to other hazards, such as fire.
This document does not address safety issues associated with explosion or fire with respect to OFCSs deployed in explosive atmospheres.
This fourth edition cancels and replaces the third edition published in 2004, Amendment 1:2006 and Amendment 2:2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition.
a) Recommendations for individual components and subassemblies have been clarified; see Clause 1, paragraph 3.
b) C7 has been revised in accordance with IEC 60825-1:2014, but with an additional limitation related to the skin MPE; see 4.7.2.
c) Condition 2 has been changed, and a detailed description of the measurement and determination method for hazard level has been added; see 4.7.1 and 4.7.2.
d) Annex B has been moved into 4.9. Annex F has been moved forward as Annex B.
e) Clause D.4 Hazard level evaluation examples – Additional examples have been added.
f) Clause D.5 Fault analysis – Explanation and guidance has been simplified.
The contents of the corrigendum of June 2021 have been included in this copy.

Issue Date

2021-03-16

Category

MISC

Included in IECEE System

2021-05-12

Purchase webstore
Test Report Form
Testing Equipment List
DISCLAIMER: National differences

The National differences and Group differences, National Deviations and Special National conditions (SNC), are based solely on information provided to the Secretariat by the IECEE Member Bodies and/or NCBs and other sources. The IEC/IECEE is not responsible for, nor will it take any position related to, the accuracy or validity of the information provided. To verify the current status of this type of information, we recommend contacting the Member Body (MB) or National Certification Body (NCB) of the relevant country.

Group Differences are applicable for CENELEC member countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

Group/Country

Reference

Last Modified

Differences

TRF Addendum

CanadaCanada

2022-11-22

Download52 kb

Laboratory Name

City

Country

Responsible National Certification Body

Shanghai

China

Toronto

Canada

Shanghai 200436

China

Modiin

Israel

Boxborough,

United States of America

Lake Forest,

United States of America

Shanghai

China

Seoul 08389

Korea, Republic of

Shanghai

China

Beijing 100176

China

Shanghai

China

Shenzhen 518052

China

San Diego

United States of America

GORMLEY

Canada

Jiangsu

China

Shenzhen, Guangdong

China

München

Germany

Mie 516-0021

Japan

Fremont,

United States of America

Research Triangle Park

United States of America

Id

Name

City

Country

13336

Toronto, Ontario

Canada

13360

Arnhem

Netherlands

20269

Modiin

Israel

13371

Kista

Sweden

13424

IL 60005

United States of America

13356

Seoul

Korea, Republic of

13334

BRUSSELS 1070

Belgium

13354

Yokohama

Japan

13427

Singapore 609937

Singapore

13346

München

Germany

13423

Northbrook

United States of America

Id

Name

City

Country

25774

Sunnyvale,

United States of America

13365

Singapore

Singapore

13345

Nürnberg

Germany