Lavorwash spa
Lavorwash spa
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2013-09-27 |
Further information
Stage | Country | Name |
---|---|---|
1 | Germany |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
HOUS | IEC 60335-1:2020 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-1:2010 | accepted clauses | 2017-09-01 | |
HOUS | IEC 60335-1:2010/AMD1:2013 | accepted clauses | 2013-09-27 | |
HOUS | IEC 60335-1:2010/AMD2:2016 | all clauses except clauses 13, 16, 21, 27, 30. | 2019-03-06 | |
HOUS | IEC 60335-2-2:2019 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-2:2009 | accepted clauses | 2017-09-01 | |
HOUS | IEC 60335-2-2:2009/AMD1:2012 | accepted clauses | 2013-09-27 | |
HOUS | IEC 60335-2-2:2009/AMD2:2016 | all clauses except clauses 13, 16, 21, 27, 30. | 2019-03-06 | |
HOUS | IEC 60335-2-10:2021 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-10:2002 | all clauses except clauses 13, 16, 21, 27, 30. | 2019-03-06 | |
HOUS | IEC 60335-2-10:2002/AMD1:2008 | all clauses except clauses 13, 16, 21, 27, 30. | 2019-03-06 | |
HOUS | IEC 60335-2-54:2008 | accepted clauses | 2013-09-27 | |
HOUS | IEC 60335-2-54:2008/AMD1:2015 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-54:2008/AMD2:2019 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-67:2021 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-67:2012 | all clauses except clauses 13, 16, 21, 27, 30. | 2019-03-06 | |
HOUS | IEC 60335-2-67:2012/AMD1:2016 | all clauses except clauses 13, 16, 21, 27, 30. | 2019-03-06 | |
HOUS | IEC 60335-2-68:2021 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-68:2012 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-68:2012/AMD1:2016 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-69:2021 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-69:2016 | all clauses except clauses 13, 16, 21, 27, 30. | 2019-03-06 | |
HOUS | IEC 60335-2-69:2012 | accepted clauses | 2013-09-27 | |
HOUS | IEC 60335-2-69:2002 | accepted clauses | 2017-09-01 | |
HOUS | IEC 60335-2-69:2002/AMD1:2004 | accepted clauses | 2013-09-27 | |
HOUS | IEC 60335-2-69:2002/AMD2:2007 | accepted clauses | 2013-09-27 | |
HOUS | IEC 60335-2-72:2021 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-72:2016 | all clauses except clauses 13, 16, 21, 27, 30. | 2019-03-06 | |
HOUS | IEC 60335-2-79:2021 | All clauses except 13-16-20-21- 27-29-30 | 2022-08-04 | |
HOUS | IEC 60335-2-79:2016 | all clauses except clauses 13, 16, 21, 27, 30. | 2019-03-06 | |
HOUS | IEC 60335-2-79:2012 | accepted clauses | 2013-09-27 | |
HOUS | IEC 60335-2-79:2002 | accepted clauses | 2013-09-27 | |
HOUS | IEC 60335-2-79:2002/AMD1:2004 | accepted clauses | 2013-09-27 | |
HOUS | IEC 60335-2-79:2002/AMD2:2007 | accepted clauses | 2013-09-27 |