Shanghai Sansi Electronic Engineering Co., Ltd.
Shanghai Sansi Electronic Engineering Co., Ltd.
Address(es) |
|
Website | Not available |
Status | MEMBER |
Acceptance date | 2018-09-06 |
Further information
Stage | Country | Name |
---|---|---|
2 | Germany |
LEGEND: Scope Limitations
- RA : Audio amplifiers with audio power > 0,5 Watts excluded
- RC : Apparatus with connection(s) to a cable distribution system excluded
- RSH : Shredders excluded
- RT : Apparatus with connection(s) to a telecommunication network excluded
- RV : CRT (cathode ray tubes)/ picture tubes, plasma/LCD or other video apparatus excluded
- ROUT : Equipment intended for installation outdoors excluded
- RWPT : Wireless power transmitter excluded
Category | Name | Tests/Clauses | Acceptance Date | Responsible National Certification Body |
---|---|---|---|---|
LITE | IEC 60598-1:2020 | Luminaires, All clauses except Cl.3.4: Test of marking Cl.4.4: Lampholders Cl.4.5 - Starterholders, Cl.4.10: Double and reinforced insulation Cl.4.11.6: Electro-mechanical contact systems Cl.4.12: Screws and connections (mechanical) and glands Cl.4.13: Mechanical strength Cl.4.14.1: Test E: For clip-mounted luminaires Cl.4.15: Flammable materials Cl.4.20: Rough service luminaires – Vibration requirements Cl.4.21: Protective shield Cl.4.24: Photobiological hazards Cl.4.26: Short-circuit protection Cl.4.28: Fxing for thermal sensing control Cl.4.29: Luminaire with non replaceable light source. Cl.5.2.10.3: Tests for cord anchorage Cl.8: PROTECTION AGAINST ELECTRIC SHOCK Cl.9.2.9: IP X8 test Cl.9.2.10: IP X9 test Cl.12.6: Thermal test (failed windings in lamp control gear Cl.12.7: Thermal test in regard to fault conditions in lamp control gear or electronic devices incorporated in thermoplastic Cl.13: RESISTANCE TO HEAT, FIRE AND TRACKING Cl.14: Screw terminals Cl.15: Screwless terminals and electrical connections | 2021-10-13 | |
LITE | IEC 60598-1:2014 | Luminaires, All clauses exceptCl.3.4: Test of markingCl.4.4: Lampholders Cl.4.5 - Starterholders,Cl.4.10: Double and reinforced insulation Cl.4.11.6: Electro-mechanical contact systemsCl.4.12: Screws and connections (mechanical) and glandsCl.4.13: Mechanical strengthCl.4.14.1: Test E: For clip-mounted luminairesCl.4.15: Flammable materials Cl.4.20: Rough service luminaires – Vibration requirementsCl.4.21: Protective shieldCl.4.24: Photobiological hazards Cl.4.26: Short-circuit protectionCl.4.28: Fxing for thermal sensing control Cl.4.29: Luminaire with non replaceable light source.Cl.5.2.10.3: Tests for cord anchorageCl.8: PROTECTION AGAINST ELECTRIC SHOCKCl.9.2.9: IP X8 testCl.12.6: Thermal test (failed windings in lamp control gear Cl.12.7: Thermal test in regard to fault conditions in lamp control gear or electronic devices incorporated in thermoplasticCl.13: RESISTANCE TO HEAT, FIRE AND TRACKINGCl.14: Screw terminalsCl.15: Screwless terminals and electrical connections | 2018-09-06 | |
LITE | IEC 60598-1:2014/AMD1:2017 | Luminaires, All clauses exceptCl.3.4: Test of markingCl.4.4: Lampholders Cl.4.5 - Starterholders,Cl.4.10: Double and reinforced insulation Cl.4.11.6: Electro-mechanical contact systemsCl.4.12: Screws and connections (mechanical) and glandsCl.4.13: Mechanical strengthCl.4.14.1: Test E: For clip-mounted luminairesCl.4.15: Flammable materials Cl.4.20: Rough service luminaires – Vibration requirementsCl.4.21: Protective shieldCl.4.24: Photobiological hazards Cl.4.26: Short-circuit protectionCl.4.28: Fxing for thermal sensing control Cl.4.29: Luminaire with non replaceable light source.Cl.5.2.10.3: Tests for cord anchorageCl.8: PROTECTION AGAINST ELECTRIC SHOCKCl.9.2.9: IP X8 testCl.12.6: Thermal test (failed windings in lamp control gear Cl.12.7: Thermal test in regard to fault conditions in lamp control gear or electronic devices incorporated in thermoplasticCl.13: RESISTANCE TO HEAT, FIRE AND TRACKINGCl.14: Screw terminalsCl.15: Screwless terminals and electrical connections | 2020-09-28 | |
LITE | IEC 60598-2-3:2002 | Luminaires, All clauses exceptCl.3.4: Test of markingCl.4.4: Lampholders Cl.4.5 - Starterholders,Cl.4.10: Double and reinforced insulation Cl.4.11.6: Electro-mechanical contact systemsCl.4.12: Screws and connections (mechanical) and glandsCl.4.13: Mechanical strengthCl.4.14.1: Test E: For clip-mounted luminairesCl.4.15: Flammable materials Cl.4.20: Rough service luminaires – Vibration requirementsCl.4.21: Protective shieldCl.4.24: Photobiological hazards Cl.4.26: Short-circuit protectionCl.4.28: Fxing for thermal sensing control Cl.4.29: Luminaire with non replaceable light source.Cl.5.2.10.3: Tests for cord anchorageCl.8: PROTECTION AGAINST ELECTRIC SHOCKCl.9.2.9: IP X8 testCl.12.6: Thermal test (failed windings in lamp control gear Cl.12.7: Thermal test in regard to fault conditions in lamp control gear or electronic devices incorporated in thermoplasticCl.13: RESISTANCE TO HEAT, FIRE AND TRACKINGCl.14: Screw terminalsCl.15: Screwless terminals and electrical connectionsCl.3.6.3: The wind-force test | 2018-09-06 | |
LITE | IEC 60598-2-3:2002/AMD1:2011 | Luminaires, All clauses exceptCl.3.4: Test of markingCl.4.4: Lampholders Cl.4.5 - Starterholders,Cl.4.10: Double and reinforced insulation Cl.4.11.6: Electro-mechanical contact systemsCl.4.12: Screws and connections (mechanical) and glandsCl.4.13: Mechanical strengthCl.4.14.1: Test E: For clip-mounted luminairesCl.4.15: Flammable materials Cl.4.20: Rough service luminaires – Vibration requirementsCl.4.21: Protective shieldCl.4.24: Photobiological hazards Cl.4.26: Short-circuit protectionCl.4.28: Fxing for thermal sensing control Cl.4.29: Luminaire with non replaceable light source.Cl.5.2.10.3: Tests for cord anchorageCl.8: PROTECTION AGAINST ELECTRIC SHOCKCl.9.2.9: IP X8 testCl.12.6: Thermal test (failed windings in lamp control gear Cl.12.7: Thermal test in regard to fault conditions in lamp control gear or electronic devices incorporated in thermoplasticCl.13: RESISTANCE TO HEAT, FIRE AND TRACKINGCl.14: Screw terminalsCl.15: Screwless terminals and electrical connectionsCl.3.6.3: The wind-force testCl.3.6.5.2: Protection by the use of high impact resistant glass | 2018-09-06 | |
LITE | IEC 61347-1:2015 | Lamp controlgear, exceptCl.7.2: Durability and legibility of markingCl.8: TerminalsCl.10: Protection against accidental contact with live partscl.13: Thermal endurance test for windings of ballasts Cl.14: Fault conditions Cl.15.2: Printed circuits Cl.17: Screws, current-carrying parts and connectionsCl.18: Resistance to heat, fire and trackingAnnex A, B, C, D, E, G, H, I, L, N, O | 2018-09-06 | |
LITE | IEC 61347-1:2015/AMD1:2017 | Lamp controlgear, exceptCl.7.2: Durability and legibility of markingCl.8: TerminalsCl.10: Protection against accidental contact with live partscl.13: Thermal endurance test for windings of ballastsIECEE OD-2048-F2-2:2019 © IEC 2019 – 11 – Ed.1.050183399 003 2019-06-05Disclaimer: This document is controlled and has been released electronically.Only the version on the IECEE Website is the current document versionCl.14: Fault conditions Cl.15.2: Printed circuits Cl.17: Screws, current-carrying parts and connectionsCl.18: Resistance to heat, fire and trackingAnnex A, B, C, D, E, G, H, I, L, N, O | 2018-09-06 | |
LITE | IEC 61347-2-13:2014 | Lamp controlgear, exceptCl.7.2: Durability and legibility of markingCl.8: TerminalsCl.10: Protection against accidental contact with live partscl.13: Thermal endurance test for windings of ballasts Cl.14: Fault conditions Cl.15.2: Printed circuits Cl.17: Screws, current-carrying parts and connectionsCl.18: Resistance to heat, fire and trackingAnnex A, B, C, D, E, G, H, I, L, N, OCl.15: Transformer heating | 2018-09-06 | |
LITE | IEC 61347-2-13:2014/AMD1:2016 | Lamp controlgear, exceptCl.7.2: Durability and legibility of markingCl.8: TerminalsCl.10: Protection against accidental contact with live partscl.13: Thermal endurance test for windings of ballasts Cl.14: Fault conditions Cl.15.2: Printed circuits Cl.17: Screws, current-carrying parts and connectionsCl.18: Resistance to heat, fire and trackingAnnex A, B, C, D, E, G, H, I, L, N, OCl.15: Transformer heating | 2018-09-06 |